Plumbing Fixture Count

Determine code-required plumbing fixture counts based on occupancy and building type.

Before

Sample Problem

Calculate fixtures for office building (US):
• Occupancy: 150 people
• Gender split: 50% male / 50% female
• Building type: Business (B occupancy)
• Code: IBC 2021 / IPC 2021
• ADA compliance required
After

AI-Generated Solution

FIXTURE REQUIREMENTS (IPC Table 403.1):

MALE RESTROOMS (75 occupants):
• Water closets: 2 required (1 must be ADA)
• Urinals: 1 required (may substitute 1 WC)
• Lavatories: 2 required (1 must be ADA)

FEMALE RESTROOMS (75 occupants):
• Water closets: 3 required (1 must be ADA)
• Lavatories: 2 required (1 must be ADA)

TOTAL FIXTURE COUNT:
• Water closets: 5 total (2 ADA)
• Urinals: 1
• Lavatories: 4 (2 ADA)
• Drinking fountains: 1 (hi-lo required)

✅ IPC 2021 & ADA 2010 COMPLIANT

Key Results

Total Fixtures
11 plumbing fixtures
ADA Fixtures
4 accessible
Estimated Cost
$15,000 - $25,000
Code References
IPC Table 403.1

Common Use Cases

Office core planning
Tenant improvement
Code compliance reviews
Restroom sizing

Professional Review Required

This demo shows AI-generated output for preliminary design purposes only. All calculations must be verified by a licensed Professional Engineer (PE). Cognitive BuiltWorld assumes no liability for designs based on AI outputs.