Back to All Demos
Structural
Advanced

Steel Connection Design

Design bolted and welded steel connections for beams, columns, and bracing.

Before

Sample Problem

Design a bolted shear connection for the following:
- Beam: W21×62 (A992 steel, Fy = 50 ksi)
- Column: W14×90
- Shear Force: V_u = 85 kips (LRFD)
- Connection Type: Double-angle shear connection
- Bolts: 3/4" A325-N (threads in shear plane)
- Angles: L4×4×3/8, A36 steel
- AISC 360-16 code

Determine number of bolts and check angle capacity.
After

AI-Generated Solution

BOLTED SHEAR CONNECTION DESIGN (AISC 360-16)

1. BOLT SHEAR CAPACITY (Table J3.2)
   3/4" A325-N bolt (threads in shear plane)
   r_n = 17.9 kips per shear plane

   Double Shear Connection:
   φR_n = 0.75 × 2 × 17.9 = 26.85 kips per bolt

2. NUMBER OF BOLTS REQUIRED
   n = V_u / φR_n
   n = 85 kips / 26.85 kips
   n = 3.17 bolts

   Use 4 bolts (vertical arrangement)

3. BOLT SPACING CHECK
   Min spacing = 2.67d = 2.67 × 0.75" = 2"
   Use 3" vertical spacing ✓ OK

   Edge distance:
   Min = 1.25" (Table J3.4)
   Use 1.5" from beam web ✓ OK

4. ANGLE CAPACITY (Block Shear)
   L4×4×3/8, gross area = 2.86 in²

   Shear yielding path:
   A_gv = (3 spaces × 3" + 1.5") × 0.375" = 4.22 in²

   Shear rupture path:
   A_nv = [10.5" - 3.5 × (0.75" + 0.125")] × 0.375"
   A_nv = 2.78 in²

   Tension rupture:
   A_nt = (4" - 0.5 × 0.875") × 0.375" = 1.34 in²

   φR_n = 0.75[0.6F_uA_nv + U_bsF_uA_nt]
   φR_n = 0.75[0.6(58)(2.78) + 1.0(58)(1.34)]
   φR_n = 130.7 kips > 85 kips ✓ OK

5. WELD TO COLUMN (If required)
   E70 fillet weld, 3/16" size
   Weld strength = 1.392 kips/in (AISC Table J2.4)

   Required length = 85 / (2 × 1.392)
   L_req = 30.5"

   Use (2) angles with 11" weld length each = 22" total
   Add 50% for end returns ≈ 33" > 30.5" ✓ OK

FINAL DESIGN:
✓ (2) L4×4×3/8 × 11" long angles
✓ (4) 3/4" A325-N bolts @ 3" o.c.
✓ 3/16" fillet weld to column flange
✓ Connection capacity = 107 kips > 85 kips

Key Results

Number of Bolts
4 - 3/4" A325
Angle Size
L4×4×3/8 × 11"
Connection Capacity
107 kips
Utilization Ratio
79%

Common Use Cases

Beam-to-column connections
Bracing connections
Truss joints
Seismic detailing

Professional Review Required

This demo shows AI-generated output for preliminary design purposes only. All calculations must be verified by a licensed Professional Engineer (PE). Cognitive BuiltWorld assumes no liability for designs based on AI outputs.

Get Full Access to This Tool

Premium members get the complete prompt text, multiple templates, advanced features, and priority support.